Design the future

Geothermal distributors

  • Information
  • Gallery
  • Download
 Geothermal distributors

FRANK geothermal valves are tested for leaks at the factory. With different designs and sizes, FRANK covers the requirements of construction projects of any complexity.

Plastic distributor type 2061/2062 with flow meters

Compact, modular geothermal distributor made of glass-fiber-reinforced polyamide for working with soil probes, energy baskets or a horizontal collector.

Execution:

  • Flow meters and control valves in the flow line
  • All circuits contain shut-off valves on the supply and non-return lines
  • Modular structure of individual components
  • Install individual distributor segments without tools
  • The manifold segments are self-sealing with an O-ring
  • Circuit Connection - AG 1
  • Section size is 100 mm
  • Accessories:

  • Connecting fittings for PE pipe (MS compression fitting) -d 25, 32 and 40 mm
  • Screw connection with d32 welding socket
  • Pressure gauge
  • Thermometer
  • Геотермальні розподільники FRANK

    Plastic distributor type 2063-2065

  • The structure of the distributor is similar to the collector type 2061, but the connection of the circuits is carried out by means of plug connections:
  • PE - union for welding with radial sealing through a sealing ring
  • Stainless steel clamp
  • Geothermal circuits can be disconnected separately using shut-off valves
  • Flowmeter integrated in the supply pipe with control valve (Type 2063: distribution set without flowmeter and plug / welding connection; Type 2064: distribution set with flowmeter 7-32 l / min and plug / welding connection; Type 2065: distribution set with a flowmeter of 4-20 l / min and connection plug / under welding)
  • Геотермальні розподільники FRANK

    Modular plastic manifold type 3060 for high consumption

    Modular plastic manifold with flow meters and welding plug.

    Execution:

  • Compact plastic manifold in modular design
  • For volumetric flow rates up to 16 m³ / h
  • Turning with built-in flow meters and shut-off / control valves / Feed with shut-off valves
  • Seal manifold connection
  • Secure the plug connection with a clamp
  • Recommended total size of approximately 10-15 contours, depending on volume flow
  • Supplied as a modular system with pre-assembled kits for 2 or 3 circuits (each VL + RL module) and a basic package with connection to a heat pump and wall brackets
  • Геотермальні розподільники FRANK
    Gallery