Object: private house / Lviv
Installed equipment:
The heat pump heats, hot water and cools the house. The backup heat source is an electric heater with a capacity of 6 kW integrated into the heat pump. Heating and cooling of the house is carried out thanks to duct fan coils. The facility uses a system of «passive» cooling. The low soil temperature is directly used to cool the building, without the operation of the heat pump compressor. The facility is also equipped with a Pichler heat recovery ventilation system and flexible Fränkische polymer air ducts.